Advanced Seismic Receiver (ASR-1)
ASR-1 (HP) Satellite Specifications | |
Length | 35” (884mm) |
Diameter | 3” (76mm) |
Weight | 41lbs (19kg) |
Max locking range | 12” (305mm) Standard or 22” (559mm) with an arm extender |
Max locking force | 300 lbs (Standard Arm) |
Temperature | 400oF (204oC) Analogue, 385oF (195oC) Digital (180oC for pre 2016 electronics modules AS270/271/273). |
Pressure | 25,000psi (1750 bar) |
Sensors | 3 Component Gimbal – Sensor SM-4 HT 10Hz |
3 Component Fixed – SMC 2400 15Hz Omni- Dual/Quad | |
Well Deviation Control | 0o-95o |
Panels | GPP/GMP & GSP-1 (Digital) |
DCP-2 & GSP-1 (Analogue) | |
Coming Soon: | GMP – (New Power Panel with integrated Wireline QC & Telemetry Config Options – replaces GPP) |
System Specifications
Downhole Specifications | |||
Max. No. of Satellites | 62 | ||
Telemetry | Sample interval | Bandwidth Hz | ASR’s (DFU in use) |
1/4ms | 1600 | 8 (15) | |
1/2ms | 800 | 16 (30) | |
1ms | 400 | 32 (60) | |
1.5ms | 266 | 48 (62) | |
Dynamic Range | >112dB @ 0dB pre-gain (minimum) | ||
A/D convertor | 24 bit Delta-Sigma | ||
Distortion | <0.02% | ||
DC offset | Self-calibrating | ||
Max. data rate |
4Mbit/second (X-Generation AS272 Digitiser +) | ||
Min. data rate | 256kbit/second |
Surface Specifications | |
Recording panel | GPP and GSP-1 (Digital) DCP-2 and GSP-1 (Analogue) |
Software | ASL Acquisition Suite and Copy of VSProwess© Processing Software. See Software for latest release. |
Cable equalisation | Fully automatic using internal DSP chip |
Down-going data rate | 2 kbit/second |
Airgun firing pulse | 60 V, 30ms |
Test system | Fully automatic with comprehensive report generation |
PC Interface | USB |
Power Requirements | 100/230 V AC, 47-63 Hz universal input, 30 watts |
Operating Temp | 32-104°F (0-40°C) |
Enclosure | Standard 19” rack mounting |
ORDER THIS PRODUCT
CALL OUR SALES TEAM
+44 (0) 1458 270000